High-precision titratioN automatic buret and the new titration control method enables accurate titration. Up to four units can be connected and measured simultaneously.
Main Feautures
- 4-channels titration
Combination of up to 4 potentiometric and Karl Fischer titrators can be connected in one Multi-controller with simultaneous measurements.
- Automatic pH calibration
Equipped with automatic stability judgement function. Automation from pH calibration to sample measurement is possible when using MST.
- Reanalysis function
Reanalysis to change end point detection is now possible.
Inflection point ⇔ set potential ⇔ front intersection ⇔ rear intersection ⇔ V intersection
- LIMS connection
Multi-controller transfers measuring data automatically to the network simultaneously.
- Data Integrity
GT-310 with integrated data integrity feature, comes with strong and smart support for data protection and management without a dedicated PC. Audit trail function is provided as an option in the data integrity version of the GT-310 software.
Audit trail | (option) |
---|---|
User Management, Login Password, Permission Management | ✓ |
Validation | ✓ |
Backup | USB memory/USB-HDD/networking |
Maintenance management | ✓ |
Five-step certification of measurement results | (option) |
Networking with LIMS | ✓ |
Main Specifications
Type of titration | Potentiometric titration (acid-base, redox, chelatometric, precipitation) polarization and conductivity titration (optional) |
---|---|
Detection range | pH: 0~14 -2000mV to +2000mV |
End point detection | Test titration General titration Petroleum neutralization value-official method/conventional method, etc |
Number of files | Sample name: 99 cases, Blank value: 99 cases, Factor: 99 events,etc |
Buret accuracy | 20ml ± 0.02ml |
Resolution/Minimum drip rate | 0.001ml |
Number of stored data | 9999 cases |
GLP-compliant function | Validation (electrode inspection, injection volume inspection, measurement inspection), history display of pH calibration, user registration function with password, |
Dimensions and weight | MC: Approx. 245(W) x 160(D) x 215(H) mm STR: Approx. 110(W) x 165(D) x 415(H) mm 5.5kg BRT: Approx. 127(W) x 378(D) x 260(H) mm 1.2kg |
【Option】
Multi-sample Titrator GT-310MST (Sample Changer Function)
GT-310, with a Multi-controller and burets, GT-310MST performs multi sample / various sample measurement continuously. Both 12 and 24 beaker storage are available.
Specifications
Number of stored beakers | 12 or 24 |
---|---|
Beaker size | 100/200 ml beaker (options: 100/200/300 ml tall beaker, 100/200ml disposable beaker, 100 ml Erlenmeyer flask) |
Electrode washing | Automatic washing in dedicated washing pot, Showering, and sinking washing |
Table rotation method | Turntable, rotation driven by DC motor |
Beaker detection | Optical sensor |
Dimensions and weight | MC: Approx. 414(W) x 489(D) x 423(H) mm 15.4kg |